GDHG-108A CT/PT Analyzer

GDHG-108A CT/PT Analyzer

Brief Description:

GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. 


Product Detail

Product Tags

GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection.

Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT.

Features

Using the voltage detection principle to measure CT and PT.
To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards.
No external auxiliary equipment, a single machine can complete all test items.
With high speed micro printer: real-time print the test result.
Using intelligent controller, operation is simple.
5inch LCD screen display.
Automatically given CT/PT (excitation) knee point value.
Auto display 5% and 10% error curve.
Save 3000 groups data, it won't lost after power off.
With USB port. The data can be saved in USB disk and read by PC (WORD format file). 
Light weight, less than 22kg, suitable for onsite testing.

Specifications

Main functions

CT (voltage detection) PT
Voltage current characteristic curve (excitation characteristic) • Voltage current characteristic curve (excitation characteristic)
Auto calculate knee point value Auto calculate knee point value
Auto display 5% and 10% error curve Turns ratio measurement
• Turns ratio measurement Polarity determination
Polarity determination • AC Hipot Test
• AC Hipot Test Demagnetization of iron core
Demagnetization of iron core • Voltage multiple can be adjusted (1.2-2.5times) in PT VA characteristic test
• Accurate limit factor(ALF) measurement  

Main parameters 

Item Parameter
Power supply AC220V±10%, 50Hz
Output 0-1000Vrms(20peak)
Accuracy of excitation measurement ≤ 0.4% of the reading+0.6% of the range
CT turns ratio measurement Range ≤3000A/1A(15000A/5A)
Accuracy ±1.0%
PT turns ratio measurement Range ≤500KV
Accuracy ±1.0%
Operation environment Temperature: 10℃ ~ 40℃, humidity: ≤90%, Altitude: ≤1000m
Dimension&Weight Dimension: 440mm × 360mm × 340mm   Weight: ≤22Kg
Accessories
CT/PT Tester 1piece
Test Lead 1set
Earth cable 1piece
Power cord 1piece
2A fuse 2pcs
User's guide 1copy
Factory test report 1copy

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us